L-com Releases New OM5 Fiber Cables for High-Speed Data Center Applications

L-com has added a new series of OM5 fiber cable assemblies to address high-speed data center applications. OM5 fiber cable is able to support short wavelength division multiplexing (SWDM) which reduces the parallel fiber count by at least a factor of four. This allows for the use of just two fibers (not eight) for transmitting 40 Gbps and 100 Gbps Ethernet, thus reducing overall fiber counts typically required for higher speed applications. 

Not Exactly in the Limelight – Yet.

Is OM5 needed? Last year the IEEE P802.3cm task force began working on a new standard for 400 Gb/s over multimode fiber that in addition to 400GBASE-SR8 over eight lanes (16 fibers total) using 24- or 16-fiber MPO connectors also includes 400GBASE-SR4.2 that operates over four two-short wavelength division multiplexed (SWDM) lanes (8 fibers total) using a standard 12-fiber MPO. Since OM5 is optimized for SWDM, this could finally push it into the limelight. However, since the new standard leverages existing two-wavelength technology that will ensure operation up to 100 meters of OM4 cabling, the question remains as to whether people will make the leap.

Ericsson pledges $100M to build smart factory in U.S.

Ericsson plans to build its first fully-automated smart factory in the U.S. that will produce advanced antenna system radios for 5G deployments in North America. Ericsson’s direct investment is about $100 million, which will kick in during the third quarter of this year, the company told FierceWireless. The Swedish vendor said the radios will be designed to boost network capacity and coverage, including in rural areas, as well as 5G radios for urban areas.

Mixed Mindfulness

When it comes to a cabling infrastructure, not all media and applications are always the same. So for each and every link, it’s important to be aware of what you’re testing—from both a media type and application standpoint. Often customers will determine that they only need Category 5e or Category 6 for some applications and Category 6A for others, or they may realize the need to upgrade some but not all links.

TIA-569-E Telecom Pathways and Spaces standard published

The TIA has published the ANSI/TIA-569-E standard, Telecommunications Pathways and Spaces. The “E” revision supersedes the 569-D standard, which was published in 2015. ANSI/TIA-569-E was developed by the TIA’s TR-42.3 Subcommittee.  Major changes from the previous edition include updated references; incorporation of revised temperature and humidity requirements originally published in ANSI/TIA-569-D-1; and incorporation of additional pathway and space considerations for supporting remote powering over twisted-pair cabling originally published in ANSI/TIA-569-D-2.