Legrand and DASAN Zhone Solutions Announce Joint Marketing Agreement

Legrand and DASAN Zhone Solutions have agreed to jointly market DZS’s Passive Optical LAN (POL) solution, FiberLAN™ and Legrand’s complete range of network connectivity, physical support, power and thermal management solutions. Under the terms of the agreement, Legrand and DZS are together targeting the smart building market with a complete solution set that is designed to provide end customers with the infrastructure and equipment needed to deploy a full POL solution.

Cable Testing 101: Measuring Insertion Loss for Fiber and Copper

The amount of energy that a signal loses as it travels along a cable link used to be referred to as attenuation.The longer the cable, the greater the attenuation. For network cabling, standards now more correctly use the term “insertion loss” which refers to the loss of the signal strength at the far end of a link and includes the attenuation caused by the cable and any connection points along the way (i.e., connectors and splices), as well as any signal lost to reflections of the signal. Despite this correction in terminology, the limits, test procedures and requirements have not changed.

Prototyping a Future of “Hands Free” Testing

Fluke Networks has teamed up with RealWear of Vancouver, WA to demonstrate a “hands free” solution for fiber endface inspection using the RealWear HMT-1 wearable rugged Android tablet. The demonstration will pair the Fluke Networks FI-3000 FiberInspector™ Pro camera with the HMT-1, allowing the inspection of Multiple Push-On (MPO) fiber optic connectors to ensure error-free communications. Come and give it a try at #BICSIFall next week in Las Vegas.

Rosenberger to unveil data center, fiber-optic innovations at 2019 BICSI Fall show

At the Fall BICSI Conference, Rosenberger will introduce its Lyra Intelligent Micro Data Center platform ‘in a box’ for IoT edge and 5G MEC applications, as well as its FTH-9 Plus Wave ODF cabinet for Seismic Zone 4 “Ring of Fire”-sensitive data center installations. The LYRA IMDC provides power, cooling, UPS, cable management and cloud remote-monitoring. It can be installed in less than 3 hours with 40% space-savings versus traditional data center installations. Applications include small data centers, office areas and edge deployments.

Connecting with the right fiber optic connector: Part 1

Which fiber optic connector is right for your job? You need to evaluate your customer’s priorities to consider cost, time and performance. Cost is an easy factor to look at and its importance depends on the budget for the job. In a large project where the budget has some flexibility, the connector’s cost may not make a difference. If you have a project where the budget is tight, the cost could be what keeps your project on target.

TIA and TSDSI Announce Collaboration to Advance ICT Standards

TIA and the Telecommunications Standards Development Society, India (TSDSI), have signed a memorandum of understanding  to advance ICT standards with a special focus on smart buildings and wireless infrastructure. They will share technical knowledge and best practices, participate in events, facilitate discussions with standards-related forums, and work together to identify potential areas for cooperation.

White Paper: The Role of PoE in the Modern Connected Enterprise

Power over Ethernet has become the new power grid in buildings. With new standards that allow up to 99W to be delivered, PoE has grown up and is ready to power connected devices throughout the office building, school, and hospital. Panduit’s latest ebook, The Role of PoE in the Modern Connected Enterprise, explores infrastructure considerations and emerging solutions for extending the distance of PoE delivery.

New MSA Formed to Tackle 400GE Over Multi-Mode Fiber

The 400GE BiDi MSA Group founded in July focuses on promoting interoperable 400GE optical specifications that utilize multi-mode fiber (MMF) for applications up to 100m link distances. The MSA leverages BiDi technology that has been widely deployed by Cisco and others for 40GE and 100GE applications over duplex MMF. With the arrival of 400GE applications, customers will finally have no choice but to start using MMF transceivers that require more than duplex fiber. 400GE ports can be used to aggregate traffic from 100GE ports, still leveraging the duplex MMF from 100GE BiDi modules to 400GE modules in a breakout configuration as shown in the diagram below.