Tag: Leviton

SINGLE-MODE Fiber Continues to Gain Momentum

Over the past several years, Leviton has polled network professionals about the type of fiber they would install today, and we have seen solid growth in single-mode. In the March 2020 poll of 281 network professionals, more than 60% said they would install single-mode (OS2) today over multimode types, with OM4 coming in second at 28%. This change is largely a result of decreasing cost and recent standards committee activities that continue to promote more single-mode options for higher speeds such as 200 and 400 Gb/s. As this trend continues, the market in general will find single-mode a more enticing option. Let’s take a closer look at reasons behind its rise.

Simplifying Data Center Network Design with Universal POLARITY Fiber Cassettes

Polarity means that a fiber optic link’s transmit signal at one end of the cable must match the corresponding receiver at the other end. While this concept might seem simple, it becomes more complex with multifiber cables and MPO connectors. Leviton’s new Universal Polarity Fiber Cassettes that help data center managers simplify things even further. The Base12 cassettes allow for the same interchangeable cassette on both ends of a Method B trunk in a fiber channel, reducing the complexity of a fiber network, ensuring consistent polarity, and streamlining network deployment.

Webinar: Single-Mode Fiber: The Perfect Fit For Your Evolving Enterprise

Until recently, multimode transceivers were orders of magnitude less expensive than their single-mode counterparts, making multimode the fiber of choice for many enterprise network designers. Today, the cost of single-mode transceivers has come down significantly, making the increased bandwidth and longer distances made possible by single-mode fiber much more attractive. This presentation covers: Reasons to include single-mode fiber in the enterprise network; What you need as an IT Manager and what is expected as an installer; Choices and recommendations on fiber cabling, connectors, termination and migration options; and Cleaning, testing and maintenance to ensure system longevity and performance.

Simplifying Data Center Network Design with Universal Fiber Cassettes

Polarity is a critical part of any fiber network. Polarity means that a fiber optic link’s transmit signal at one end of the cable must match the corresponding receiver at the other end. While this concept might seem simple, it becomes more complex with multifiber cables and MPO connectors. Leviton’s new Universal Polarity Fiber Cassettes allow for the same interchangeable cassette on both ends of a Method B trunk in a fiber channel, reducing the complexity of a fiber network, ensuring consistent polarity, and streamlining network deployment.

Applications for singlemode fiber-optic cabling

Singlemode fiber-optic cabling systems, once found almost exclusively in service providers’ long-haul networks or in expansive campuses, are now commonly being used in data center and enterprise networks. How deep has singlemode gotten into these networks, and how much deeper are they likely to go? That’s the topic of this month’s In-Depth discussion.

Webinar: The Key to 400G

As more cloud service providers and hyperscale data centers migrate to 200 and 400 Gb/s to support 50 and 100 Gb/s servers, active equipment manufacturers have already announced 400 Gb/s switch platforms in response to demand from data center managers. What is involved in creating the right ecosystem for 400 Gb/s Ethernet? What options to data center designers have? This webinar will provide an overview and guidance.

Should Should light leak through the fiber that’s inserted into the connecter when I use a visual fault locator?

The VFL source launches overfilled light that will surround the core of the bare fiber and extend into and through the cladding, flooding the inside of the connector body. This is normal and does not necessarily mean the fiber is damaged. The amount of light can vary by fiber and connector type. To visually check the quality of a termination, verify the intensity and quality of light exiting the opposite end of the cable under test. If the light is weak or non-existent, a damaged connector or fiber may exist.

Multifiber Mania: Understanding MPO Connections

MPO connectors are the most likely solution to migrate to 100, 200 and 400 Gb/s. If managers and contractors don’t use MPO or MTP® options and instead stick with LC connectivity, they’re going to end up limiting themselves to either long-reach transceiver applications for single mode, or some type of wave division multiplexing (WDM) technology. Getting started on using MPOs now will set organizations up for success, as higher speeds from 25 Gb/s to 400 Gb/s become the new norm.